HIOKI 3805-50 Digital HiTester 
  • For Power line distortion check (Harmonic distortion % display)
  • True RMS rectification of your harmonic-ridden signal, Basic accuracy ±0.09%
  • For cooling equipment maintenance (Simultaneous 2-point temperature measurement)

Product Details

HIOKI 3805-50 Digital HiTester

Demonstrate the Power of your DMM during Facilities Maintenance

For Instrumentation (4 - 20mA% display). For Power line distortion check (Harmonic distortion % display). True RMS rectification of your harmonic-ridden signal, Basic accuracy ±0.09%. For cooling equipment maintenance (Simultaneous 2-point temperature measurement). Temperature scanning function (T1, T2, T1 - T2). PC communication via USB (using optional accessories)

Regarding DMM Accuracy
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.

DC Voltage : 999.9 mV to 999.9 V, 4 ranges, Basic accuracy: ±0.09% rdg. ±2 dgt.

AC Voltage 40 to 2kHz : 999.9 mV to 999.9 V, 4 ranges, Basic accuracy: ±1.0% rdg. ±5 dgt., (true RMS rectified, crest factor 3 or less)

Resistance : 999.9 O to 99.99 MO, 6 ranges, Basic accuracy: ±0.3% rdg. ±3 dgt.

DC Current : 999.9 µA to 9.99 A, 5 ranges, Basic accuracy: ±0.1% rdg. ±3 dgt.

AC Current 40 to 2kHz : 999.9 µA to 9.99 A, 5 ranges, Basic accuracy: ±1% rdg. ±5 dgt., (true RMS rectified, crest factor 3 or less)

Hz (Frequency) : 9.999 Hz to 200.0 kHz, Accuracy: ±0.03% rdg. ±3 dgt., Input level: 0.5 V to 1000 V, minimum frequency 0.5 Hz

Temperature (Thermocouple) : [K] -40 °C to 1372 °C, [J] -40 °C to 1200 °C, Basic accuracy: ±0.3% rdg. ±3 °C, add to the accuracy of the temperature probe

Continuity buzzer : 100 digits or less at resistance measurement

Diode check : Open terminal voltage: 3.5 V or less, Testing current 0.46 mA

Capacitance : 9.999 µF (resolution 1 nF) to 9.999 mF (resolution 1 µF), 4 ranges, Basic accuracy: ±2% rdg. ± 5 dgt.

Other functions : Recording value of maximum, minimum, averaging, Trigger-hold, Refresh-hold, Harmonic %, 4-20mA % , Relative value, Auto-power save, USB communication

Display : Digital LCD, max. 9999 digits

Sampling rate : 7 times/s, 4 times/s (at capacitance measurement up to 100 mF), 1 time/s (at frequency measurement range)

Power supply : 6F22 (Stacked manganese battery) × 1, Continuous use: 30 hr 6LR61 (Stacked alkaline battery) × 1, Continuous use: 60 hr

Dimensions, mass : 83mm (3.27 in) W × 178mm (7.01 in) H × 58mm (2.28 in) D, 400g (14.1 oz) (with holster and battery)

Supplied accessories : TEST LEAD×1, Holster×1, Instruction Manual×1, Battery(6LR61)×1(for trial purposes only)

HIOKI 3239-01 Digital HiTester Benchtop 5-1/2 digits DMM with 4-terminal resistance measurement and high-accuracy Multi functional and high precision model, with 4-terminal resistance ...
FLUKE 175 Digital Multimeter The three models of the new 170 Series are the new benchmarks for general purpose multimeters. They set the standard with a combination of precision, features...
RISHABH RISH Multi 11 Handheld Digital Multimeter The DATA HOLD function makes it possible to hold the digitally displayed measured value. It is ensured that no freak value but the actual...
HIOKI 3256-50 Digital HiTester Terminal shutter interlock mechanism for safety 3256-50: Average rectified type, AC voltage detection simply by placing the instrument close the insulate...
ISKRA MI 7022 Portable Multimeter The MI 7022 portable digital temperature meter is intended for temperature measurement in the range between -50° and +200°C. Probe for in-depth temperatu...