HIOKI 3532-50 LCR HiTester 
  • High precision measurement of ±0.08% basic accuracy
  • Interactive touch panel operation
  • Print measurement values and comparator results (option)

Product Details

HIOKI 3532-50 LCR HiTester

Increased measurement speed of up to 5msec !
42Hz to 5MHz, wide test frequency range LCR meter

High speed measurement of 5ms. High precision measurement of ±0.08% basic accuracy. Interactive touch panel operation. Zoom feature for easy viewing. Print measurement values and comparator results (option).

This product is not supplied with measurement probes or test fixtures.
Please select and purchase the measurement probe or test fixture options appropriate for your application separately.

Basic specifications (Accuracy guaranteed for 6 months)

Measurement parameters : |Z|,|Y|, ?, Rp, Rs(ESR), G, X, B, Cp, Cs, Lp, Ls, D(tan d), Q

Measurement ranges : 100 mO to 100 MO, 10 ranges (All parameters defined by |Z|)

Extent of Measurement Impedance : |Z|, R, X: 10.00 mO to 200.00 MO (depending on condition)
?: -180.00° to +180.00°, C: 0.3200 pF to 370.00 mF, L: 16.000 nH to 750.00 kH, D: 0.00001 to 9.99999, Q: 0.01 to 999.99, |Y|, G, B: 5.0000 nS to 99.999 S (Note: All measurement ranges except for |Z| are for reference only)

Basic accuracy : |Z|: ±0.08% rdg., ?: ±0.05°

Source frequency : 42Hz to 5MHz (0.1Hz to 1kHz steps)

Measurement signal level : 10mV to 5V rms (up to 1MHz), 50mV to 1V rms (1MHz to 5MHz), (1mV rms steps) 10µA to 100mA rms (up to 1MHz), 50µA to 20mA rms (1MHz to 5MHz), (10µA rms steps)

Output resistance : 50O

Display : LCD with backlight display, 99999 (3, 4, or 5 digits unit setting possible)

Measurement times : FAST: 5ms, NORMAL: 21ms,
SLOW 1: 72ms, SLOW 2: 140 ms (typical values for displaying |Z|)

DC bias : Superimposed DC voltage, DC current to source signal (used with the optional DC bias unit and constant voltage or current source equipment)

Function : Comparator, External input/Output (EXT. I/O), GP-IB or RS-232C interface (option)
(Note: RS-232C interface required if used with the Printer 9442.)

Power consumption : Selectable 100, 120, 220 or 240V AC ±10%, 50/60Hz, 50VA max.

Dimensions, mass : 352mm (13.86in) W × 124mm (4.88in) H × 323mm (12.72in) D, 6.5kg (229.3oz)

Supplied accessories : Power cord × 1, Spare fuse × 1

HIOKI 3504-50 C HiTester High-speed, Large-capacitance MLCC Inspection with Constant Voltage High speed measurement of 2ms. Supports C measurements with voltage dependency characterist...
HIOKI 3511-50 LCR HiTester Compact & Powerful dedicated LCR measurement in 5 milli-second timeframes High speed measurement: 5 ms (1 kHz) or 13 ms (120 Hz). High precision accuracy: ± ...
HIOKI 3522-50 LCR HiTester Increased measurement speed of up to 5msec ! DC, 1mHz to 100kHz, wide test frequency range LCR meter High speed measurement of 5ms. High precision measureme...
HIOKI 3504-60 C HiTester High-speed, Large-capacitance MLCC Inspection with Constant Voltage High speed measurement of 2ms. Supports C measurements with voltage dependency characterist...
HIOKI 3504-40 C HiTester High-speed, Large-capacitance MLCC Inspection with Constant Voltage High speed measurement of 2ms. Supports C measurements with voltage dependency characterist...