Free Call Australia : 1 800 834 991

Related Products

Hioki 3390-10 Power Analyzer

HIOKI 3390-10 Power Analyzer 
  • Switch from one range to another and still maintain the same ±0.1% accuracy on all ranges
  • Advanced motor analysis functions (measures the electric angle and supports vector control)
  • Inverter power measurement with the convenience of clamp on sensors

Product Details

HIOKI 3390-10 Power Analyzer Maximizing the Efficiency of Energy Conversion

Super precise ±0.1% accuracy model to meet the demanding needs of today. Switch from one range to another and still maintain the same ±0.1% accuracy on all ranges. Guaranteed accuracy period is extended another 6 months from the basic Model 3390 (other functions remain the same). Advanced motor analysis functions (measures the electric angle and supports vector control). High-speed harmonic analysis function (50 ms data refresh rate). Noise analysis function for inverters (using FFT analysis technology). Inverter power measurement with the convenience of clamp on sensors

Data sheets for specific combinations of Model 3390-10 and current sensors available upon request. Optional current sensor and voltage cord are necessary to measure current or power parameters.

Measurement line type : Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, threephase 4-wire, Voltage 4 channels, Current 4 channels, Isolated between each channel

Measurement items : Voltage, Current, Voltage/current waveform peak, Active power, Reactive power, Apparent power, Power factor, Phase angle, Frequency, Current integration, Power integration, Efficiency, Loss, Voltage/current ripple factor

Noise measurement (FFT processing) : RMS spectrum of voltage/current

Harmonic measurement : RMS value, Content factor, Phase angle, Total distortion, Disequilibrium factor

Additional functions (With optional 9791 or 9793 installed in the main unit) : Torque, Rotation, Frequency, Slip, or Motor output

Harmonic measurement : Input: 4 ch, Synchronization frequency range: 0.5 Hz to 5 kHz,

Number of harmonic orders : Max. 100th order

Noise measurement : Number of channels: 1 ch (select one channel from CH1 to CH4),

Maximum analysis frequency : 100 k/ 50 k/ 20 k/ 10 k/ 5 k/ 2 kHz

Measurement range : Voltage range: 15 to 1500 V, 7 ranges

Current range : 400 mA to 500 A (depends on current sensor, 20A/ 50A/ 200A/ or 500A rated)

Power range : 6.0000 W to 2.2500 MW (depends on combination of voltage and current range)

Frequency range : 0.5 Hz to 5 kHz

Basic accuracy : (45Hz to 66Hz)

Voltage : ±0.05 % rdg. ±0.05 % f.s.

Current : ±0.05 % rdg. ±0.05 % f.s. (Defined at combined accuracy with dedicated sensors)

Active power : ±0.05 % rdg. ±0.05 % f.s. (Defined at combined accuracy with dedicated sensors)

Accuracy for the high accuracy Models 3390-10 and Current Sensors are not defined individually. Please use these products in combination to obtain ±0.1% accuracy.

Synchronization frequency range : 0.5 Hz to 5 kHz

Frequency band : DC, 0.5 Hz to 150 kHz

Data update rate : 50 ms (For harmonic measurement, depends on the synchronization frequency when less than 45 Hz)

Display refresh rate : 200 ms (Independent of internal data update rate; waveform and FFT depend on the screen)

Data save interval : OFF, 50 msec to 500 msec, 1 sec to 30 sec, 1 minute to 60 minutes, 15 settings

External interfaces : LAN, USB (communication/ memory), RS-232C, CF card, Synchronization control

Power supply : 100 to 240 V AC, 50/60 Hz, 140 VA max.

Dimensions, mass 340 mm (13.39 in) W × 170 mm (6.69 in) H × 157 mm (6.18 in) D, 4.8 kg (169.3 oz)

Supplied accessories : Instruction Manual for Model 3390 ×1, Instruction Manual for Model 3390-10 ×1, Measurement Guide ×1, Power cord ×1, USB cable ×1, D-sub connector ×1 (when 9792 or 9793 is installed), Color label ×2

Specifications for the Motor Testing Option (Accuracy guaranteed for 1 year)

Number of input channels 3 channels, CH A : Torque signal input (DC V / Frequency input), CH B: Rotation signal input (DC V / Pulse input), CH Z: Z-phase signal input (Pulse input)

Measurement item : Voltage, Torque, Rotation, Frequency, Slip, Motor power

DC V (CH A/ B) Measurement range : ±1 V/ ±5 V/ ±10 V, Accuracy: ±0.1 % rdg. ±0.1 % f.s.

Frequency (CH A) Effective amplitude range : ±5 V peak, Measurement band: 1 kHz to 100 kHz

Pulse (CH B) Detection level : (Low) 0.5 V or less, (High) 2.0 V or more, Measurement band: 1 Hz to 200 kHz

Pulse (CH Z) Detection level : (Low) 0.5 V or less, (High) 2.0 V or more, Measurement band: 0.1 Hz to 1 kHz

HIOKI PW3198 Power Quality Analyzer The New World Standard for Power Quality Analysis, with recording & analyzing according to Class A requirements for PQAs Verify power problems in acco...
HIOKI 3194 Motor / Harmonic HiTester Up to 6 input channels for analysis of inverter motors and high-order harmonics. The 3194 provides Analysis of high-order harmonics up to the 3000th orde...
ELSPEC BLACKBOX Firmware Release. Class A: Extended support per latest 61000-4-30 Class A revision. Many new parameters, averaged intervals, and more! Device Configuration FILE: Based on X...
ELSPEC Investigator. Elspec Investigator is a client application that communicates, receives, and displays data from the PQSCADA server system . The communication performed uses a standard H...
ELSPEC G3500 BLACKBOX Portable Power Quality Analyzer. Built on the same innovative technology as the BLACKBOX fixed Power Quality Meter (PQA), the ELSPEC G3500 BLACKBOX Portable Digital Pow...