Product Details
HIOKI 9290-10 Clamp-On Adapter
Easy-to-use, current to current transformer. AC current up to 1500 A, secondary current 1/10 of primary.
Basic specifications (Accuracy guaranteed for 1 year)
Rated primary current : AC 1000 A continued (Maximum 1500 A for 5 minutes or shorter)
Rated secondary current : AC 100 A (10 : 1 CT ratio)
Amplitude Accuracy : ±1.5% rdg.
Phase Accuracy : ±1.0° or less
Frequency characteristic : Amplitude: 20 Hz to 5 kHz: ±2.0 % rdg. (deviation from accuracy)
Phase: 20 Hz to 5 kHz: ±1.0° or less (deviation from accuracy)
Max. rated voltage to earth : 600 V AC rms (insulated wire)
Core jaw dia. : f55 mm (2.17 in) or 80 mm (3.15 in) × 20 mm (0.79 in) busbar
Dimensions, mass : 99.5 mm (3.92 in) W × 188 mm (7.40 in) H × 42 mm (1.65 in) D, 580 g (20.5 oz), cord length 3 m (9.84 ft)
Supplied accessories : Instruction manual ×1, Mark band ×6
Note: Cannot use with the Model CT 9279
Product Description
HIOKI 9290-10 Clamp-On Adapter is the best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The 9290-10 is a clamp-on adapter rated for 1500A AC, and features a 10:1 CT ratio. In addition to the large clamp diameter, broad frequency characteristics and good phase characteristics, the CT reliably provides Hioki clamp on power meters with expanded range and large current measurements.