Free Call Australia : 1 800 834 991

Related Products

Hioki 3802-50 Digital HiTester

HIOKI 3802-50 Digital HiTester 
  • High-performance model 3801-50 (AC+DC mode/ Temperature/ Dutyratio measurement)
  • Can record to internal memory, maximum, minimum, or average value
  • For PC measurement corresponds to USB communication (optional)

Product Details

HIOKI 3802-50 Digital HiTester

High Performance, Superior Functionality, and Advanced Safety

High-performance model 3801-50 (AC+DC mode/ Temperature/ Dutyratio measurement)
Can record to internal memory, maximum, minimum, or average value
High-precision measurement at the 3801-50 Basic accuracy ±0.025 %, 1 µV minimum resolution
Depend on a dual-display, can display two parameter
Convenient back-light display on dark environment
For PC measurement corresponds to USB communication (optional)

Regarding DMM Accuracy
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.

Basic specifications (Accuracy guaranteed for 1 year)

DC Voltage /51000 dgt. : 51.000 mV to 1000.0 V, 7 ranges
Basic accuracy: ±0.03 % rdg. ±5 dgt.

AC Voltage /45 to 1 kHz : 51.000 mV to 1000.0 V, 7 ranges
Basic accuracy: ±0.6 % rdg. ±25 dgt.
Frequency characteristics: 30 Hz - 30 kHz

Resistance : 510.00 O to 510.00 MO, 510.00 nS, 8 ranges (3802-50: up to 51.000 MO, 510.00 nS, 7 ranges)
Basic accuracy: ±0.08 % rdg. ±5 dgt.

DC Current : 510.00 µA to 10.000 A, 6 ranges
Basic accuracy: ±0.1 % rdg. ±25 dgt.

AC Current /45 to 2 kHz : 510.00 µA to 10.000 A, 6 ranges
Basic accuracy: ±0.8 %rdg. ±20 dgt.
Frequency characteristics: 30 Hz - 20 kHz

C (capacitance) : 9.999 nF (resolution 1 pF) to 99.99 mF (rosolution 10 µF), 8 ranges
Basic accuracy: ±1.5 % rdg. ±5 dgt.

Continuity buzzer : 1000 digits or less at resistance measurement

Diode check : Open terminal voltage: 4.8 V, Testing current: 1 mA

Hz (Frequency, Volt function) : 99.999 Hz to 999.99 kHz 5 ranges, ±0.02 % rdg. ±3 dgt.

Hz counter : Not available
Accuracy: ±0.002 % rdg. ±3 dgt.

Duty ratio : 99.99 % , Basic accuracy: ±0.3 %/kHz ±0.3 %

Pulse width : 510.00 ms to 1999.9 ms, Accuracy: ±0.2 % rdg. ±3 dgt. at 10 µs over pulse width

Temperature measure : -200.0 °C to 1372.0 °C (Thermo-couple K), -210.0 °C to 1200.0 °C (Thermocouple J), Accuracy: ±0.3 % rdg. ±3 °C add probe accuracy, (the 3802-50: K type only)

Pulse output : Not available

Other function : Not available
dBm mode, Recoding (Max./ Min. / Ave.), Relative value, Peak hold, Trriger hold, Auto-power save, Terminal A improper connection warning, Back light

Display : Digital/ LCD, max. 51000 digits

Sample rate : 3.75 times/s (V and, A measurement)

Power supply : Stacked battery (6F22 or 6LR61) ×1, Continuous use: 50 hours (6LR61)

Dimensions and mass : 100W (3.94in) × 202H (7.95in) × 57D (2.24in) mm, 680 g (24.0 oz) (with holster and battery)

Supplied accessories : TEST LEAD×1, Strap×1, Holster×1, Instruction Manual×1, Stacked Alkaline Battery (6LR61)×1 (for trial purposes only)

HIOKI 3256-50 Digital HiTester Terminal shutter interlock mechanism for safety 3256-50: Average rectified type, AC voltage detection simply by placing the instrument close the insulate...
FLUKE 177 Digital Multimeter The three models of the new 170 Series are the new benchmarks for general purpose multimeters. They set the standard with a combination of precision, features...